<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Tehran University Medical Journal</title>
<title_fa>مجله دانشکده پزشکی، دانشگاه علوم پزشکی تهران</title_fa>
<short_title>Tehran Univ Med J</short_title>
<subject>Medical Sciences</subject>
<web_url>http://tumj.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1683-1764</journal_id_issn>
<journal_id_issn_online>1735-7322</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.18869/acadpub.tumj</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1389</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2010</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>68</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>به دام افتادن کاتتر اپیدورال به هنگام خارج‌سازی: گزارش موردی</title_fa>
	<title>Epidural catheter fragment entrapment: a case report</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa></content_type_fa>
	<content_type></content_type>
	<abstract_fa>زمینه و هد ف: خارج نمودن کاتتر اپیدورال از بدن بیمار به ندرت سخت می شود. ولی بروز آن برای پزشک و بیمار
مشکل ساز خواهد بود . معرف یبیما : ر برای پسر 17 ساله ای جهت جراحی ثابت نمودن استخوان فمور و بی دردی بعد
از عمل کاتتر اپیدورال گذاشته شد. روز سوم بعد از عمل به دلیل چسبندگی کاتتر اپیدورال تلاش زیادی برای خارج
نمودن آن نمودیم ولی کاتتر شکسته شد و قطعه ای از آن در بدن بیمار جا ماند. در سی تی اسکن ، محل آن خارج از
یافت شد. به دلیل آن که بیمار هیچ علامتی نداشت اقدامی برای خارج L3-L فضای اپیدورال در فضای ساب لامینار 4
نمودن آن انجام نشد و از طریق درمانگاه بیمار پی گیری شد. نتیج هگیر : ی شناخت روش ها ی عمل ی ی افتن محل و
علت گیر افتادن کاتتر اپیدورال و اندیکاسیون های جراحی آن بر ای متخصص ین بیهوش ی بس یار اهمی ت دارد. انجام
سی تی اسکن در تعیین محل و علت به دام افتادن کاتتر و راهنمایی و تسهیل در انجام عمل جراحی سودمند می باشد.
</abstract_fa>
	<abstract>Background: Epidural catheters are seldom difficult to remove from patients. The breakage of the catheters is uncommon, troublesome and occasionally dangerous.
Case  presentation:  A  lumbar  epidural  catheter  inserted  in  a  17  year-old  man  for applying anesthesia for internal fixation of femur fracture and subsequent postoperativeepidural analgesia. In the third postoperative day, during unsuccessful attempt for removing the catheter, it was broken and was retained in his back. A CT- scan was performed and shows a fragment of catheter in the sub- laminar ligament between L3 and L4 without any connection with epidural space. As the patient had no complaint the fractured fragment was left in site and he was just followed up in the clinic.
Conclusion: The knowledge of practical method in locating the retained epidural catheter, and the indication for surgical removal are very important. CT- scan is useful in  showing  the  mechanism  and  locating  the  epidural  catheter  entrapment  and facilitating surgical follow-up.


</abstract>
	<keyword_fa>اپیدورال,کاتتر,عوارض</keyword_fa>
	<keyword>Epidural,catheter,entrapment</keyword>
	<start_page>257</start_page>
	<end_page>260</end_page>
	<web_url>http://tumj.tums.ac.ir/browse.php?a_code=A-10-25-356&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohammadi</first_name>
	<middle_name></middle_name>
	<last_name>M</last_name>
	<suffix></suffix>
	<first_name_fa>مصطفی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>گروه بیهوشی بیمارستان اما م خمینی  دانشگاه  علوم پزشکی  تهران </affiliation_fa>
	 </author>


	<author>
	<first_name>Barkhordari</first_name>
	<middle_name></middle_name>
	<last_name>Kh</last_name>
	<suffix></suffix>
	<first_name_fa>خسرو</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>برخورداری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>گروه بیهوشی بیمارستان مرکز قلب تهران     دانشگاه  علوم پزشکی  تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Khajavi</first_name>
	<middle_name></middle_name>
	<last_name>MR</last_name>
	<suffix></suffix>
	<first_name_fa>محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خاجوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>khajavim@tums.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>گروه بیهوشی بیمارستان سینا     دانشگاه  علوم پزشکی  تهران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
