<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Tehran University Medical Journal</title>
<title_fa>مجله دانشکده پزشکی، دانشگاه علوم پزشکی تهران</title_fa>
<short_title>Tehran Univ Med J</short_title>
<subject>Medical Sciences</subject>
<web_url>http://tumj.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1683-1764</journal_id_issn>
<journal_id_issn_online>1735-7322</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.18869/acadpub.tumj</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1388</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2009</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<volume>67</volume>
<number>8</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه یافته‌های آنژیوگرافی عروق کلیوی به روش توموگرافی کامپیوتری چندلایه با  یافته‌های جراحی در افراد زنده دهنده کلیه</title_fa>
	<title>Multidetector computed tomography (CT) angiography of renal vasculature versus operative findings in living renal donors</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa></content_type_fa>
	<content_type></content_type>
	<abstract_fa>
&lt;p dir=&quot;rtl&quot; style=&quot;text-align: justify&quot;&gt;&lt;!--stripped--&gt; Normal


  0


  


  


  


  


  false


  false


  false


  


  EN-US


  X-NONE


  AR-SA


  


   


   


   


   


   


   


   


   


   


   


   


  


  MicrosoftInternetExplorer4 &lt;!--stripped--&gt;&lt;!--stripped--&gt; &lt;!--stripped--&gt; &lt;!--stripped--&gt;
&lt;style&gt;


 /* Style Definitions */


 table.MsoNormalTable


	{mso-style-name:&quot;Table Normal&quot;


	mso-tstyle-rowband-size:0


	mso-tstyle-colband-size:0


	mso-style-noshow:yes


	mso-style-priority:99


	mso-style-qformat:yes


	mso-style-parent:&quot;&quot;


	mso-padding-alt:0in 5.4pt 0in 5.4pt


	mso-para-margin:0in


	mso-para-margin-bottom:.0001pt


	mso-pagination:widow-orphan


	font-size:11.0pt


	font-family:&quot;Calibri&quot;,&quot;sans-serif&quot;


	mso-ascii-font-family:Calibri


	mso-ascii-theme-font:minor-latin


	mso-fareast-font-family:&quot;Times New Roman&quot;


	mso-fareast-theme-font:minor-fareast


	mso-hansi-font-family:Calibri


	mso-hansi-theme-font:minor-latin


	mso-bidi-font-family:Arial


	mso-bidi-theme-font:minor-bidi}


&lt;/style&gt;
&lt;!--stripped--&gt; &lt;strong&gt;زمینه و هدف&lt;/strong&gt;: تصمیم‌گیری در مورد اینکه
کدام کلیه دهنده زنده نفرکتومی شود، در هر سرویس جراحی متفاوت است ولی آناتومی عروقی
ساده‌تر و بدون آنومالی از مهمترین دلایل انتخاب یک کلیه است. بنابراین نفرکتومی
در دهنده زنده نیاز به بررسی دقیق آناتومی عروق کلیوی دارد. به نظرمی‌رسد سی‌تی ‌مولتی‌دتکتور
بهترین روش برای تعیین آنومالی‌های
عروقی کلیه و سیستم ادراری باشد. &lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p dir=&quot;rtl&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;روش بررسی&lt;/strong&gt;: در این مطالعه 59
دهنده زنده کلیه توسط سی‌تی آنژیوگرافی چند لایه تحت بررسی قرار گرفتند. از تمام
دهندگان، پس از تزریق ماده حاجب، تصاویر سی‌تی با ضخامت 6/0 میلی‌متر دریافت شد و
بازسازی و پردازش سه بعدی صورت گرفت و وضعیت شریان‌های فرعی، زود شاخه شدن شریان
کلیوی، تعداد وریدها و حالب‌ها مورد بررسی قرار گرفت و نتایج به‌دست آمده با نتایج
نفرکتومی بیماران مقایسه شد. &lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p dir=&quot;rtl&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;یافته‌ها&lt;/strong&gt;: سی‌تی آنژیوگرافی
چند لایه شیوع شریان فرعی را 4/3% با دقت 98% و زود شاخه‌شدن شریان کلیوی را در
4/8% موارد با دقت 100% گزارش کرد. ورید کلیوی متعدد در 4/8% موارد دیده شد و دقت
تشخیصی این روش 98% بود. حالب دوگانه در هیچ‌کدام از بیماران مشاهده نشد. &lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p dir=&quot;rtl&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;نتیجه‌گیری&lt;/strong&gt;: دقت تشخیصی این روش در دیدن شریان و ورید فرعی حدود 98% و در زود شاخه شدن شریان کلیوی 100% است. این نتایج با
آنژیوگرافی معمولی قابل مقایسه است و طبق مطالعات این روش در مقایسه با ام‌آر-
آنژیوگرافی و دیژیتال ساب‌تراکشن آنژیوگرافی، ارزش بیشتری دارد، کم تهاجمی‌تر است
و می‌توان آن را روش تشخیصی طلایی در تشخیص آنومالی‌های عروقی و سیستم ادراری در
دهندگان زنده کلیه نام برد.&lt;/p&gt;
</abstract_fa>
	<abstract>
&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Background:&lt;/strong&gt; In kidney transplantation decision about the proper kidney donation is different between surgeons, but simple vasculature anatomy and a kidney without abnormalities are the most important reasons of choosing a kidney. Therefore    complete assessment of renal vessels of a live donor with noninvasive techniques is a necessity for nephrectomy. For delineation of the kidney vasculature anomalies and urinary system abnormalities, Multi-Detector CT seems to be excellent method for evaluation.&lt;br&gt;&lt;strong&gt;Methods:&lt;/strong&gt; In this study 59 live donors were assessed with Multi-Detector CT Angiography. After injection of contrast media, we acquired images with 0.6 mm slice thickness. Processing and three dimentional reconstructions were done and the accessory arteries, early branching of main renal artery, the number of main renal vessels and the ureters were assessed. Findings were compared with the nephrectomy results.&lt;br&gt;&lt;strong&gt;Results: &lt;/strong&gt;In Multi-Detector CT Angiography the prevalence of accessory renal artery was 3/4% with 98% accuracy, early branching of main renal artery was 8/4% with 100% accuracy. Multiplicity of renal veins was seen in 8/4% of donors with 98% accuracy. Duplicated ureter was not seen in any of the donors.&lt;br&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Conclusions:&lt;/strong&gt; The accuracy of CT Angiography is 95% for depicting accessory renal artery and multiple renal artery and 100% for early branching. These results were comparable with findings in conventional angiography. Studies showed this method  more valuable than M.R. Angiography and digital subtraction angiography. It is less invasive and can be named as the gold standard method in the diagnosis of anomalies of vessels &amp; collecting system in live donors. &lt;/p&gt;
</abstract>
	<keyword_fa>پیوند کلیه،شریان کلیوی،توموگرافی،آنژیوگرافی،اهدا کننده زنده</keyword_fa>
	<keyword>Kidney,renal artery,computed tomography,angiography</keyword>
	<start_page>569</start_page>
	<end_page>573</end_page>
	<web_url>http://tumj.tums.ac.ir/browse.php?a_code=A-10-25-426&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Sagheb</first_name>
	<middle_name></middle_name>
	<last_name>S</last_name>
	<suffix></suffix>
	<first_name_fa>سوده</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ثاقب</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Tarzamni</first_name>
	<middle_name></middle_name>
	<last_name>MK</last_name>
	<suffix></suffix>
	<first_name_fa>محمدکاظم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>طرزمنی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Javadrashid</first_name>
	<middle_name></middle_name>
	<last_name>R</last_name>
	<suffix></suffix>
	<first_name_fa>رضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جواد رشید</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Zomorodi</first_name>
	<middle_name></middle_name>
	<last_name>A</last_name>
	<suffix></suffix>
	<first_name_fa>افشار</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>زمردی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Bahluli</first_name>
	<middle_name></middle_name>
	<last_name>A</last_name>
	<suffix></suffix>
	<first_name_fa>ابوالفضل</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بهلولی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
