<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Tehran University Medical Journal</title>
<title_fa>مجله دانشکده پزشکی، دانشگاه علوم پزشکی تهران</title_fa>
<short_title>Tehran Univ Med J</short_title>
<subject>Medical Sciences</subject>
<web_url>http://tumj.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1683-1764</journal_id_issn>
<journal_id_issn_online>1735-7322</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.18869/acadpub.tumj</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1388</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2009</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>67</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>محاسبه دوز اعضاء ناشی از معاینه سی‌تی‌اسکن معمولی سر با استفاده از نرم‌افزار ImPACT در بیمارستان‌های وابسته به دانشگاه علوم پزشکی تهران</title_fa>
	<title>Assessment of Brain absorbed X-ray dose during CT- Scan using ImPACT software in Tehran Univeristy hospitals</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa></content_type_fa>
	<content_type></content_type>
	<abstract_fa>
&lt;p dir=&quot;rtl&quot; style=&quot;text-align: justify&quot;&gt;&lt;!--stripped--&gt; 800x600 &lt;!--stripped--&gt; &lt;strong&gt;زمینه و هدف&lt;/strong&gt;: سی‌تی‌اسکن اولین بار
در سال 1972 میلادی در معاینات کلینیکی مورد استفاده قرار گرفت و هم‌اکنون یکی از
روش‌های رایج تشخیصی است. در مطالعه سال 1998 توسط سازمان ملی حفاظت پرتوی
بریتانیا، مشخص گردید اگرچه فقط 2% کل معاینات پرتو تشخیصی مربوط به سی‌تی‌اسکن
است ولی سهم آن در دوز دریافتی بیماران از کل معاینات تشخیصی با اشعه ایکس 20% می‌باشد.
هدف از این مطالعه تدوین پروتکلی برای بیمارستان‌های تابعه دانشگاه علوم پزشکی
تهران براساس میزان دوز رسیده به بیمار و راهنمایی بیمار جهت مراجعه درست به هر
بیمارستان براساس نوع وخامت بیماری می‌باشد. &lt;br&gt;&lt;/p&gt;&lt;p dir=&quot;rtl&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;روش
بررسی&lt;/strong&gt;:
در این تحقیق، به منظور محاسبه دوز اعضاء و دوز موثر به کمک نرم‌افزار ImPACT، اطلاعات
مربوط به بیماران شامل قد، وزن، جنس و شرایط پرتونگاری در یک فرم مخصوص ثبت گردید.
با استفاده از این اطلاعات و وارد نمودن آن در فایل ورودی نرم‌افزار ImPACT دوز اعضاء و موثر برای
150 بیمار (تحت معاینه سی‌تی‌اسکن معمولی سر) محاسبه گردید. &lt;strong&gt;&lt;br&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p dir=&quot;rtl&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;یافته‌ها&lt;/strong&gt;: بیشترین دوز مغز، برای بیماران مورد معاینه در
بیمارستان امام‌خمینی به‌دست آمد. در حالی‌که بیماران مورد معاینه در بیمارستان
امیراعلم کمترین دوز در بین پنج مرکز دریافت داشتند. ماکزیمم دوز موثر بیماران در
این مطالعه از مقدار گزارش شده در نشریه سال 1991 NRPB کمتر می‌باشد. &lt;strong&gt;&lt;br&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p dir=&quot;rtl&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;نتیجه‌گیری&lt;/strong&gt;: نتایج حاصل از اندازه‌گیری دوز موثر و اعضا در دو مرکز
یاد شده با یک نوع دستگاه (EX/Toshiba Xvision) می‌تواند موید این باشد که طریقه استفاده از
دستگاه و میزان mAs, Kvp آن عامل مهمتری از نوع
دستگاه می‌باشد. چرا که هم ماکزیمم دوز و هم مینیمم دوز در یک نوع دستگاه ولی در
دو مرکز مختلف واقع شده است.&lt;/p&gt;
&lt;p&gt;&lt;!--stripped--&gt; Normal
  0
  
  
  
  
  false
  false
  false
  
  EN-GB
  X-NONE
  AR-SA
  
   
   
   
   
   
   
   
   
   
  
  MicrosoftInternetExplorer4 &lt;!--stripped--&gt;&lt;!--stripped--&gt; &lt;!--stripped--&gt;&lt;!--stripped--&gt;
&lt;style&gt;
 /* Style Definitions */
 table.MsoNormalTable
	{mso-style-name:&quot;Table Normal&quot;
	mso-tstyle-rowband-size:0
	mso-tstyle-colband-size:0
	mso-style-noshow:yes
	mso-style-priority:99
	mso-style-parent:&quot;&quot;
	mso-padding-alt:0cm 5.4pt 0cm 5.4pt
	mso-para-margin:0cm
	mso-para-margin-bottom:.0001pt
	mso-pagination:widow-orphan
	font-size:10.0pt
	font-family:&quot;Times New Roman&quot;,&quot;serif&quot;}
&lt;/style&gt;
&lt;!--stripped--&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>
&lt;p style=&quot;text-align: justify&quot;&gt;&lt;!--stripped--&gt; Normal


  0


  


  


  


  


  false


  false


  false


  


  EN-US


  X-NONE


  AR-SA


  


   


   


   


   


   


   


   


   


   


   


   


  


  MicrosoftInternetExplorer4 &lt;!--stripped--&gt;&lt;!--stripped--&gt; &lt;!--stripped--&gt;&lt;!--stripped--&gt; !mso]&gt; 
&lt;ob&lt;illegal tag&gt;ject classid=&quot;clsid:38481807-CA0E-42D2-BF39-B33AF135CC4D&quot; id=ieooui&gt;
&lt;/object&gt;
&lt;style&gt;


st1&quot;:*{behavior:url(#ieooui) }


&lt;/style&gt;
&lt;!--stripped--&gt; &lt;!--stripped--&gt;
&lt;style&gt;


 /* Style Definitions */


 table.MsoNormalTable


	{mso-style-name:&quot;Table Normal&quot;


	mso-tstyle-rowband-size:0


	mso-tstyle-colband-size:0


	mso-style-noshow:yes


	mso-style-priority:99


	mso-style-qformat:yes


	mso-style-parent:&quot;&quot;


	mso-padding-alt:0cm 5.4pt 0cm 5.4pt


	mso-para-margin:0cm


	mso-para-margin-bottom:.0001pt


	mso-pagination:widow-orphan


	font-size:11.0pt


	font-family:&quot;Calibri&quot;,&quot;sans-serif&quot;


	mso-ascii-font-family:Calibri


	mso-ascii-theme-font:minor-latin


	mso-fareast-font-family:&quot;Times New Roman&quot;


	mso-fareast-theme-font:minor-fareast


	mso-hansi-font-family:Calibri


	mso-hansi-theme-font:minor-latin


	mso-bidi-font-family:Arial


	mso-bidi-theme-font:minor-bidi}


&lt;/style&gt;
&lt;!--stripped--&gt; &lt;strong&gt;Background&lt;/strong&gt;&lt;strong&gt;:&lt;/strong&gt; CT scan was first introduced into clinical
practice in 1972, and since then has
grown into one of the predominant diagnostic procedures. In
1998, the UK National
Radiological Protection
Board reported that 20%
of the national collective dose from medical X-ray
examinations derived from CT-scans, although it
represented only 2% of all X-
ray examinations the aim of this study was to determine the X-ray
dosage received by patients in brain CT
scan.&lt;br&gt; &lt;strong&gt;Methods&lt;/strong&gt;&lt;strong&gt;:&lt;/strong&gt; In this work, we have estimated patient dose arising from CT
examination of brain in five hospitals in Tehran.
Organ and effective doses were estimated for 150
patients who underwent CT examination of
brain. &quot;ImPACT&quot;
version 0.99v was used to estimate
organ and effective dose. Brain examinations
were performed with fixed Kvp, mAs
and T (slice thickness) for each scanner. &lt;br&gt;&lt;strong&gt;Results&lt;/strong&gt;&lt;strong&gt;:&lt;/strong&gt; Patients, who were scanned by CT
of emam Khomeini center (Toshiba
Xvision /EX
Scanner), received maximum organ dose (brain) and minimum organ dose was
delivered to patients who were scanned by CT
of amir alam center (Toshiba Xvision
/EX Scanner). Maximum effective dose was 1.7
mSv acquired in this study for emam Khomeini
haspital, smaller than the corresponding value obtained by National&lt;strong&gt; &lt;/strong&gt;Radiation
Protection British
(NRPB).&lt;br&gt;&lt;strong&gt;Conclusions:&lt;/strong&gt; In
two research centers with a system, the obtained results of measurement of
effective dose and organ dose show utilization method of system and its measure
of Kvp &amp; mAs
is very important factor in comparison with type of system. Because
there are both minimum dose and maximum dose in two different centers.&lt;/p&gt;
</abstract>
	<keyword_fa>نرم‌افزار ImPACT،سی‌تی‌اسکن،دوز موثر و دوز اعضاء</keyword_fa>
	<keyword>ImPACT,CT,organ dose,effective dose</keyword>
	<start_page>257</start_page>
	<end_page>261</end_page>
	<web_url>http://tumj.tums.ac.ir/browse.php?a_code=A-10-25-457&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Khalilpour</first_name>
	<middle_name></middle_name>
	<last_name>M</last_name>
	<suffix></suffix>
	<first_name_fa>مریم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خلیل‌پور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Norouzzadeh</first_name>
	<middle_name></middle_name>
	<last_name>SH</last_name>
	<suffix></suffix>
	<first_name_fa>شبنم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نوروززاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Dadras</first_name>
	<middle_name></middle_name>
	<last_name>M</last_name>
	<suffix></suffix>
	<first_name_fa>مجید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دادرس</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
