<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Tehran University Medical Journal</title>
<title_fa>مجله دانشکده پزشکی، دانشگاه علوم پزشکی تهران</title_fa>
<short_title>Tehran Univ Med J</short_title>
<subject>Medical Sciences</subject>
<web_url>http://tumj.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1683-1764</journal_id_issn>
<journal_id_issn_online>1735-7322</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.18869/acadpub.tumj</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1397</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2018</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>76</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تاثیر کینزیوتیپ با جهت و میزان کشش مختلف بر حداکثر گشتاور اکستانسوری کوادری‌سپس و خطای بازسازی مفصل زانو در مردان سالم ورزشکار نیمه‌حرفه‌ای</title_fa>
	<title>Effects of tension of Kinesio taping application on maximum quadriceps torque and knee repositioning sense in recreationally males</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>مقاله اصیل</content_type_fa>
	<content_type>Original Article</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:yekanyw;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;زمینه و هدف:&lt;/span&gt;&lt;/strong&gt; &lt;span style=&quot;font-size:10.0pt;&quot;&gt;آسیب&#8204;های ورزشی بسیار شایع مفصل زانو می&#8204;تواند به&#8204;دلیل اختلال در قدرت عضلانی و حس عمقی مفصل زانو باشد. استفاده از کینزیوتیپ &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-size:8.0pt;&quot;&gt;(Kinesio taping)&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt; ممکن است بتواند این اختلال را کاهش دهد. بنابراین هدف از انجام این مطالعه بررسی تاثیر میزان کشش و جهت اعمال کینزیوتیپ عضله کوادری&#8204;سپس بر حس بازسازی وضعیت و بیشترین گشتاور اکستنسوری مفصل زانو بود.&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;روش بررسی: &lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;این مطالعه شبه&#8204;تجربی از مرداد تا آبان ۱۳۹۶ در آزمایشگاه بیومکانیک دانشکده توانبخشی دانشگاه علوم پزشکی تهران انجام گرفت. ۲۱ مرد سالم ورزشکار نیمه&#8204;حرفه&#8204;ای که با روش نمونه&#8204;گیری غیراحتمالی آسان انتخاب شدند، پنج جلسه به آزمایشگاه بیومکانیک مراجعه کردند. جلسه اول جهت آشنایی با آزمون&#8204;ها و در جلسات دوم تا پنجم، یکی از سه روش چسباندن کینزیوتیپ با کشش&#8204;های ۱۰۰، ۱۱۵ و ۱۴۰% ابتدا به انتها بر روی عضله کوادری&#8204;سپس و کینزیوتیپ با کشش ۱۰۰% انتها به ابتدا به&#8204;صورت تصادفی انتخاب گردید. بیشترین گشتاورکانسنتریک و اکسنتریک کوادری&#8204;سپس و خطای بازسازی وضعیت فعال و غیرفعال مفصل زانو در زاویه هدف ۶۰ درجه فلکشن با کمک &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-size:8.0pt;&quot;&gt;Biodex System 3 isokinetic dynamometer (Biodex Medical Systems, Shirley, NY, USA)&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt; اندازه&#8204;گیری شد.&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;یافته&#8204;ها:&lt;/span&gt;&lt;/strong&gt; &lt;span style=&quot;font-size:10.0pt;&quot;&gt;اعمال کینزیوتیپ ابتدا به انتها با کشش&#8204;های ۱۰۰، ۱۱۵ و ۱۴۰%، باعث کاهش معنادار خطای بازسازی وضعیت فعال و غیرفعال زاویه ۶۰ درجه زانو (۰/۰۰۱&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-size:8.0pt;&quot;&gt;P=&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;)&lt;/span&gt; &lt;span style=&quot;font-size:10.0pt;&quot;&gt;و افزایش بیشینه&#8204;ی گشتاور کانسنتریک و اکسنتریک عضله کوادری&#8204;سپس گردید (۰/۰۰۱&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-size:8.0pt;&quot;&gt;P=&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;).&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;نتیجه&#8204;گیری: &lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;کینزیوتیپ ابتدا به انتها با کشش&#8204;های ۱۰۰، ۱۱۵ و ۱۴۰%، می&#8204;تواند باعث بهبود خطای بازسازی زاویه ۶۰ درجه مفصل زانو و افزایش بیشینه&#8204;ی گشتاور کانسنتریک و اکسنتریک عضله کوادری&#8204;سپس شود.&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;
&lt;div&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Background&lt;/strong&gt;: Sports injuries of the knee joint are very common. There are both contact injuries and non-contact injuries. Contractile injuries may be due to an impairment of the knee joint position sense or a decrease of the quadriceps muscle strength. Using a Kinesio taping method may decrease this impairment. The aim of the current study was to assess the effect of direction and tension of Kinesio taping of the quadriceps muscle on repositioning sense of the knee joint and maximum concentric and eccentric torque of the knee extensors.&lt;br&gt;
&lt;strong&gt;Methods&lt;/strong&gt;: Twenty-one recreationally active healthy males, determined by convenient non-probability sampling method, participated in this quazi-experimental study. The tests were performed in biomechanics laboratory of School of Rehabilitation of Tehran University of Medical Sciences, Iran, between July to November 2017. They visited biomechanics laboratory 5 sessions. The first session was for familiarization with the main tests and signing an informed consent form. For 2 through 5 sessions, one of each Kinesio tape tension approaches of 100, 115 and 140 percent (origin to insertion direction) and 100 percent (insertion to origin direction) was randomly applied on the quadriceps muscle. Active and passive repositioning sense of the knee joint at 60-degree flexion and maximum concentric and eccentric torque of the knee extensors of the dominant extremity before and after Kinesio taping were measured using a Biodex System 3 isokinetic dynamometer (Biodex Medical Systems, Shirley, NY, USA). Order of measuring active and passive repositioning sense and maximum concentric and eccentric torque of the knee extensors were randomly selected.&lt;br&gt;
&lt;strong&gt;Results&lt;/strong&gt;: Origin to insertion Kinesio taping method with tension of 100, 115 and 140 percent significantly decreased means of active and passive repositioning sense errors (P&lt; 0.05) and changed means of maximum concentric and eccentric torque of the quadriceps muscle (P&lt; 0.05). But, insertion to origin Kinesio taping did not change significantly any parameter (P&gt; 0.05).&lt;br&gt;
&lt;strong&gt;Conclusion&lt;/strong&gt;: According to the results, Kinesio taping could influence on repositioning sense of the knee joint at 60-degree knee flexion. Maximum concentric and eccentric extensor torques was also increased.&lt;/div&gt;
&lt;div&gt;&lt;/div&gt;</abstract>
	<keyword_fa>ایزوکینتیک, کینزیوتیپ, حس عمقی, کوادری‌سپس, گشتاور</keyword_fa>
	<keyword>isokinetic, Kinesio taping, proprioception, quadriceps, torque</keyword>
	<start_page>49</start_page>
	<end_page>57</end_page>
	<web_url>http://tumj.tums.ac.ir/browse.php?a_code=A-10-3666-29&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mostafa </first_name>
	<middle_name></middle_name>
	<last_name>Mohammadi </last_name>
	<suffix></suffix>
	<first_name_fa>مصطفی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Physical Therapy, School of Rehabilitation, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>گروه فیزیوتراپی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، تهران، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Nastaran </first_name>
	<middle_name></middle_name>
	<last_name>Ghotbi </last_name>
	<suffix></suffix>
	<first_name_fa>نسترن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قطبی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Physical Therapy, School of Rehabilitation, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>گروه فیزیوتراپی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، تهران، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Seyed Mohsen </first_name>
	<middle_name></middle_name>
	<last_name>Mir </last_name>
	<suffix></suffix>
	<first_name_fa>سید محسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>میر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Physical Therapy, School of Rehabilitation, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>گروه فیزیوتراپی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، تهران، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Kazem </first_name>
	<middle_name></middle_name>
	<last_name>Malmir </last_name>
	<suffix></suffix>
	<first_name_fa>کاظم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مالمیر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>kmalmir@tums.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Physical Therapy, School of Rehabilitation, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>گروه فیزیوتراپی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، تهران، ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
