<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Tehran University Medical Journal</title>
<title_fa>مجله دانشکده پزشکی، دانشگاه علوم پزشکی تهران</title_fa>
<short_title>Tehran Univ Med J</short_title>
<subject>Medical Sciences</subject>
<web_url>http://tumj.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1683-1764</journal_id_issn>
<journal_id_issn_online>1735-7322</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.18869/acadpub.tumj</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1397</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2018</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<volume>76</volume>
<number>5</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>other</language>
	<article_id_doi></article_id_doi>
	<title_fa>معرفی ویژگی نرخ دوطیفی فرکانس‌های پایین به بالا به‌منظور تشخیص خواب عمیق از بیداری با سیگنال الکتروانسفالوگرام</title_fa>
	<title>Introduction of low to high frequencies bispectrum rate feature for deep sleep detection from awakening by electroencephalogram</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>مقاله اصیل</content_type_fa>
	<content_type>Original Article</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:yekanyw;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;زمینه و هدف:&lt;/span&gt;&lt;/strong&gt; &lt;span style=&quot;font-size:10.0pt;&quot;&gt;تشخیص دقیق خواب عمیق (خواب با امواج آهسته) از بیداری، باعث افزایش صحت طبقه&#8204;بندی خواب به&#8204;عنوان امری مهم در پزشکی خواهد شد. به&#8204;دلیل هزینه&#8204;بر و وقت&#8204;گیر بودن تعیین دستی عمق خواب می&#8204;توان با پردازش سیگنال مغزی به&#8204;صورت اتوماتیک عمق خواب را تعیین کرد. در این مطالعه ویژگی جدیدی از طیف مرتبه دوم سیگنال الکتروانسفالوگرام جهت تشخیص خواب عمیق بررسی شد.&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;روش بررسی: &lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;این مطالعه مقطعی در دانشکده فناوری&#8204;های نوین علوم پزشکی دانشگاه علوم&#8204; پزشکی اصفهان از بهمن ۱۳۹۵ تا مهر ۱۳۹۶ انجام شد. مطالعه بر روی ۲۵۹۸ تکه سیگنال الکتروانسفالوگرام دریافت&#8204;شده از هشت نفر می&#8204;باشد. در این مطالعه از مقادیر طیف مرتبه دوم الکتروانسفالوگرام تصویر خاکستری ساخته شد و با آستانه&#8204;گذاری اُتسو به تصویر باینری تبدیل گشت. سپس ویژگی جدید نسبت تعداد بیت&#8204;های سفید بالای قطر فرعی به پایین آن (نرخ دوطیفی فرکانس&#8204;های پایین به بالا) از تصویر استخراج شد.&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;یافته&#8204;ها:&lt;/span&gt;&lt;/strong&gt; &lt;span style=&quot;font-size:10.0pt;&quot;&gt;ویژگی&#8204;های مبتنی بر انرژی از جمله مهمترین روش&#8204;های پردازش سیگنال&#8204;های حیاتی هستند. نرخ دوطیفی فرکانس&#8204;های پایین به بالا، قادر است با درستی ۹۹/۵۰% حالت بیداری را از خواب عمیق جدا کند درحالی&#8204;که براساس نتایج به&#8204;دست&#8204;آمده ویژگی&#8204;های مبتنی بر انرژی چنین توانایی ندارند.&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;letter-spacing:-.4pt;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;نتیجه&#8204;گیری: &lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;letter-spacing:-.4pt;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;ویژگی معرفی&#8204;شده کارایی لازم را برای استفاده در تعیین اتوماتیک عمق خواب دارا است. درستی به&#8204;دست&#8204;آمده در تفکیک خواب عمیق و بیداری با ویژگی معرفی&#8204;شده بیش از درستی به&#8204;دست&#8204;آمده به&#8204;وسیله همه ویژگی&#8204;های مبتنی بر انرژی سیگنال است. &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.3pt;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;می&#8204;توان از این ویژگی در همه کارهایی که در آن&#8204;ها از طیف مرتبه دوم استفاده می&#8204;شود (مانند تعیین عمق بیهوشی)، استفاده کرد.&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.4pt;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;
</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Background&lt;/strong&gt;: Accurate detection of deep sleep (Due to the low frequency of the brain signal in this part of sleep, it is also called slow-wave sleep) from awakening increases the sleep staging accuracy as an important factor in medicine. Depending on the time and cost of manually determining the depth of sleep, we can automatically determine the depth of sleep by electroencephalogram (EEG) signal processing. In this paper a new EEG bispectrum based feature is introduced for deep sleep discrimination.&lt;br&gt;
&lt;strong&gt;Methods&lt;/strong&gt;: This cross-sectional study was conducted at Isfahan University of Medical Sciences, Faculty of Advanced Technologies in Medicine, from February to October 2017. In this study a gray scale image was made of electroencephalogram bispectrum amounts and converted to binary image with Otsu&amp;rsquo;s Thresholding. Then the ratio of white bits in the above of the secondary diagonal to white bits in the down of secondary diagonal (low to high frequencies bispectrum rate) is extracted as a new feature. This feature is an effective method for detecting deep sleep from awakening.&lt;br&gt;
&lt;strong&gt;Results&lt;/strong&gt;: One of the important methods in biomedical signal processing is the use of the power spectrum or signal energy. In sleep studies, energy-related features have also been used to determine the depth of sleep. Low to high frequencies bispectrum rate is able to separate deep sleep from awakening by accuracy of 99.50 percent, while energy-based features as one of the most important approaches to sleep classification do not have this ability.&lt;br&gt;
&lt;strong&gt;Conclusion&lt;/strong&gt;: In this study we show that &amp;ldquo;Low to high frequencies bispectrum rate&amp;quot; feature has this capability to use in sleep staging. It is not used in previous works. The accuracy obtained in deep sleep separation from the awakening with the introduced feature (99.50 percent) is greater than the accuracy obtained by all the energy-based features (The simultaneous use of the 6 bands energy leads to 99.42 percent accuracy). This feature indicates the ratio of the phase coupling at low frequencies to high frequencies and can be used in all cases where the bispectrum is used (such as determining the depth of anesthesia).&lt;/div&gt;
</abstract>
	<keyword_fa>مطالعات مقطعی, انرژی, پردازش سیگنال, عمق خواب</keyword_fa>
	<keyword>cross-sectional studies, energy, signal processing, sleep stages</keyword>
	<start_page>326</start_page>
	<end_page>330</end_page>
	<web_url>http://tumj.tums.ac.ir/browse.php?a_code=A-10-3666-71&amp;slc_lang=other&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Ehsan </first_name>
	<middle_name></middle_name>
	<last_name>Mohammadi </last_name>
	<suffix></suffix>
	<first_name_fa>احسان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Bioelectrics and Biomedical Engineering, School of Advanced ‎Technologies in Medicine, Isfahan University of Medical ‎Sciences, Isfahan, Iran.</affiliation>
	<affiliation_fa>گروه مهندسی پزشکی (بیوالکتریک)، دانشکده فناوری‌های نوین در علوم پزشکی، ‌دانشگاه علوم پزشکی اصفهان، اصفهان، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Saeed </first_name>
	<middle_name></middle_name>
	<last_name>Kermani </last_name>
	<suffix></suffix>
	<first_name_fa>سعید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کرمانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>kermani@med.mui.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Bioelectrics and Biomedical Engineering, School of Advanced ‎Technologies in Medicine, Isfahan University of Medical ‎Sciences, Isfahan, Iran.</affiliation>
	<affiliation_fa>گروه مهندسی پزشکی (بیوالکتریک)، دانشکده فناوری‌های نوین در علوم پزشکی، ‌دانشگاه علوم پزشکی اصفهان، اصفهان، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Babak </first_name>
	<middle_name></middle_name>
	<last_name>Amra </last_name>
	<suffix></suffix>
	<first_name_fa>بابک</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امرا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Pulmonology and ‏Somnologist, Bamdad ‏‎Respiratory Research Center‏‎, Isfahan University of Medical Sciences, ‎Isfahan, Iran.</affiliation>
	<affiliation_fa>گروه بیماری‌های تنفسی و خواب، مرکز تحقیقات تنفسی بامداد، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
